Filtration and reverse osmosis deionized water
Let's face it, if you are in the water business need deionized or reverse osmosis is your always worried about the quality. I know as a mobile business details when we have ultra clean water in our tanks we are a happy camper. We know that will make your job much easier. We also like the idea and the concept of water and no stains. Once you have already taken into account, such as reverse osmosis really works? Let me describe the process of myIndustry perspective.
In RO water pressure forces water through a thin membrane that filters between 85-95% of dissolved solids in water. No water, these non-solid water spot a car. It 'important to have in-line water filter system software before RO RO Some systems have a water softener / carbon filter / RO system in that order. This saves the life of RO membranes. RO units are in gallons per day (GPD) as measured by flowrelatively slow. Usually work 24 hours a day and the water is put into a storage tank for later use. Small RO units cost between $ 2,500 and $ 5,000 set of 4 gpm. Order would be 10 gpm, the speed with which you fill the tank, the cost for the units starts at $ 25,000.
Car washes need units that provide between 500 and 1000 gallons per day for the rinse cycles. A small device will work because 4 GPM (gallons per minute) for 60 minutes is 240 liters. So when in four hoursNight when the car wash is not used, have a thousand gallons plus. The only problem for them is that it is a thousand liters tank five feet wide and eight feet high.
An RO machine works best when clean water through it. Otherwise, let nature takes on the membranes. Then you have to reverse osmosis, but osmosis. It 'better to have a small machine works 24 hours a day as a great machine runs two hours and then stopoff. RO membranes should have a constant flow positive. Some industry leaders believe should be 12-13 hours is the maximum one race per day RO unit. They think that the equipment will last longer.
Silica, iron, aluminum and bacteria cause irreversible damage to membranes and, therefore, pre-filters are a must to keep the membranes from pollution. Fouling results when particles are deposited in the feed water suspended inside the RO. Fouling reduces the permeate flowRate. contamination by bacteria in the system does not lead to increase the conductivity of permeate until the system is extremely congested. Other particles can penetrate to increase the conductivity.
Most of silica and particulate organic contaminants can be removed with chemicals right. Bio-fouling is a problem. Pre-treatment may have little influence on pollution RO units. Just kill the bacteria will not work because the same number of particles fouling (live or dead) continue to drive the RO.The best way to manage bio-fouling and cleaning of equipment and piping upstream and filters. chlorinated water is bad and must be non-chlorinated before entering the RO group. Fouling by non-living particles is handled by filters or additional pre-sediment filter or cartridge filters with a rated output of the filter five microns or less. This can be complicated stuff and you can call a phone number for franchsior a water fair and honest local or regionalClean consultant.
Chlorine is the most common agent to chemically attack and destroy the membranes of polyamide thin film, which are commonly used in car washes. Active carbon blocks are preceded by a rule of RO units filter used. Larger units use granulated activated carbon filters or other methods. Active chlorine consuming sites on the activated carbon material over time and eventually dechlorination will diminish and eventually run out. This will allow chlorine to damagedownstream chlorine sensitive membranes in your RO unit. Carbon filter more often their manufacturers to specify to be replaced.
Most commercial RO units are too small to justify installing instrumentation to determine when cleaning. Regular cleaning can remove most contaminants and scalants. If you wait too long, permanent damage is done, and appropriate remedies will not work. If you are until you have low flow problems of waiting, the elements can be inserted in a clear andDry cleaning can be ineffective or may take several hours to get the items back to near original performance.
If you prefer, you can do the Merchant of RO on a regular contract cleaning service. It may be useful for you. Expect to pay between $ 80 to $ 160 per quarter. Watch for price gouging parties. Some companies, such as sharks. Although made in the membranes of recent years. You can have an inspection and the filter mount. So when you work allwrong, it's their responsibility, and you can pay. Make sure your contract during their lifetime warranty is tied. Periodic maintenance of reverse osmosis systems is extremely important and it is often necessary to change the filter. Water softener every month, the carbon filter every three months. Be sure to print the weekly, and Membranes need to change from time to time. Think about it.
10:00
|
ป้ายกำกับ:
deionized,
filtration,
osmosis,
reverse
|
This entry was posted on 10:00
and is filed under
deionized
,
filtration
,
osmosis
,
reverse
.
You can follow any responses to this entry through
the RSS 2.0 feed.
You can leave a response,
or trackback from your own site.
0 ความคิดเห็น:
แสดงความคิดเห็น